System-main Approx Age of System: 8 Type- R410a Metering Device- TXV SP/HP:133.2/298.2 SLT/LLT:65.4/91 VSAT/LSAT- 46.1/95.5 Superheat/Subcool-19.3/4.6 Outdoor Entering Air Temp-81 Outdoor Fan FLA- R1.8 A1.2 Compressor RLA/LRA-R R19.9/109. A 10.6/117.9 Contactor Voltage-242.4/26.9 Capacitor Rating-45/10 A40.2/8.6 Indoor Return Dry Bulb Temp-76.6 Return Wet Bulb Temp-66.3 Supply Temp- 55.4 Temperature Difference-21.2 Required Difference-15-21 Blower FLA- 2.6 Filter Sizes – 20x25x4 Changed Filters – Y Customer supplied Blew out drain line: N Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes- Arrived on site, met with customer, system was operational upon arrival. Performed ac tuneup. Found no blowout valve, or inline safety switch. Rinsed condenser coil. System is operating within specifications. Left Comfort Club brochure with customer. Customer will look at estimates for switch, valve and compressor saver. Scheduled next