30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for montgomery, tx


Map of Montgomery TX
Shane B.

Shane B.


Job Checkin

Arrived to check hall shower is not operational, customers have taken apart and could not fix it. Replaced moen positemp cartridge and reinstalled trim. Shower is now operational. Checked leak under kitchen sink found moen sprayer hose was loose to the head and leaking back through the faucet into the cabinet. Tighten hose up and no other leaks found at this time. Customer showed me the master Roman tub that was not working and has not for a while. Cold side valve body is ruined and will need to replace the valve, existing trim can be reused on new valve. Referred to Conroe tile works to get 4 pieces of tile off so we can get access. Estimates will be provided to replace pex Roman tub valve. Conroe tile works 9365399431