System- 1 Approx Age of System: 5 Refrigerant Type- R410a Metering Device- TXV SP/HP: 132/334 SLT/LLT: 64/104 VSAT/LSAT- 46/103 Superheat/Subcool- 18/7 Outdoor Entering Air Temp- 90 Outdoor Fan FLA- .82 Compressor RLA/LRA- 9.87/100 Contactor Voltage- 244/25 Capacitor Rating- 44/5 Indoor Return Dry Bulb Temp- 73 Return Wet Bulb Temp- 65 Supply Temp- 57 Temperature Difference- 16 Required Difference- 15-20 Blower FLA- 3.80 Filter Sizes – 20x30x1 Changed Filters – customer stated she will replace Blew out drain line: Y Notes- performed ac tune up x1, checked indoor air handler unit for proper operations, coils and blower are clean. Inspected drain lines No issues were visible inside. Outdoor unit washed condenser coils, checked electrical components and connections, refrigerant pressures. No issues were visible. Recommended condenser coil cleaning to keep unit working efficiently and prevent cooling issues, comfort club membership renewal and plumbing special