System- main Approx Age of System: 8 Refrigerant Type- R410a Metering Device- TXV SP/HP: 115/335 SLT/LLT: 52/90 VSAT/LSAT- 38/104 Superheat/Subcool- 14/10 Outdoor Entering Air Temp- 82 Outdoor Fan FLA- 1.10 Compressor RLA/LRA- 12.53 Contactor Voltage- 240/25 Capacitor Rating- 70/7.5 Indoor Return Dry Bulb Temp- 75 Return Wet Bulb Temp- 65 Supply Temp- 57 Temperature Difference- 17 Required Difference- 15-20 Blower FLA- 7.63 Filter Sizes – 20x25x4 Changed Filters – Y customer provided Blew out drain line: N Notes- Performed ac tune up x1, checked indoor unit for proper operations took amp draws and checked amp draws, coils are clean. Unit has no overflow protection which may cause ceiling damage in the future if drain lines back up. Will recommend complete overflow protection pack. Checked outdoor unit for proper electrical