Job Checkin

System-downstairs Approx Age of System:11 Refrigerant Type- R410a Metering Device- TXV SP/HP:79.9/216.9 SLT/LLT:62.6/74.9 VSAT/LSAT- 20.9/74.1 Superheat/Subcool-41.5/-.6 Outdoor Entering Air Temp-69 Outdoor Fan FLA- .7 Compressor RLA/LRA-8.4/55 Contactor Voltage-242.3/25.9 Capacitor Rating-44.81/5.09 Indoor Return Dry Bulb Temp-70.1 Return Wet Bulb Temp-61.5 Supply Temp- 58 Temperature Difference-12.2 Required Difference-16-20 Blower FLA- 2.1 Filter Sizes –14x25x1(2) Changed Filters – N Recently replaced Blew out drain line: N (No blow out valve ) Notes- System-upstairs Approx Age of System:11 Refrigerant Type- R410a Metering Device- TXV SP/HP:116/228.5 SLT/LLT:54.6/74.8 VSAT/LSAT- 38.7/77.8