System- upstairs Approx Age of System: 9 years Refrigerant Type- R410a Metering Device- TXV SP/HP: 111/292 SLT/LLT: 50/84 VSAT/LSAT- 36/94 Superheat/Subcool-14/10 Outdoor Entering Air Temp-81 Outdoor Fan FLA- 0.89 Compressor RLA/LRA-8.38 Contactor Voltage-241/24 Capacitor Rating-44.79/4.75 Indoor Return Dry Bulb Temp-70 Return Wet Bulb Temp-61 Supply Temp-50 Temperature Difference-20 Required Difference-16 Filter Sizes – 20x25x4 Changed Filters – No. Filters just changed Blew out drain line: Yes Returned tstat to original settings: Yes Unit operational; prior to leaving: Yes Notes- Unit is cooling properly at this time. No visible issues at this time. System- Downstairs Approx Age of System: 9 years Refrigerant Type- R410a Metering Device- TXV SP/HP: 108/289 SLT/LLT: 45/87 VSAT/LSAT- 35/93 Superheat/Subcool-10/7 Outdoor Entering Air Temp-82 Outdoor Fan FLA- 2.24 Compressor RLA/LRA-11.25 Contactor Voltage-241/24 Capacitor Rating-39.86/5.18