30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for spring, tx


Map of Spring TX
Juan  M.

Juan M.


Job Checkin

Heat Tune-up System: right side Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass 0 /ppm Airside CO: pass 0 /return ppm 0 supply ppm Flue gas carbon monoxide: pass 25 /ppm Ignition and Combustion Delayed ignition: no Flame disturbance: no Flame discoloration: no Motor Amperages and Capacitors Blower motor FLA: 3.2 Induced draft/combustion blower motor FLA: .5 Capacitor(s): pass 5 /mfd Temperature Rise Rated: 1st 20-50 Actual: 1st 41 Static Pressures Blower speed/cfm: RP .23 /FS .18 /SP .13 TESP: .41 Safety Controls Primary limit test: pass Filter sizes: 20x25x1 Changed filters: yes customer provided Notes: ________________________________________ Next Scheduled Tune Up date: Heat Tune-up System: left side Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testin