30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for tomball, tx


Map of Tomball TX
Mario S.

Mario S.


Job Checkin

System-main Approx Age of System: 7 Refrigerant Type- R410a Metering Device- TXV SP/HP:154/263 SLT/LLT:50/75 VSAT/LSAT-41/82 Superheat/Subcool-9/7 Outdoor Entering Air Temp-73 Outdoor Fan FLA- 1.1 Compressor RLA/LRA-13/110 Contactor Voltage-27/220 Capacitor Rating-45/7.5 reads 45/7.4 Indoor Return Dry Bulb Temp-72 Supply Temp-50 Temperature Difference-22 Required Difference-16-22 Blower FLA- 5.8 Filter Sizes – 20x25x1 Changed Filters – N(clean) Blew out drain line: N (no blowout valve) Notes-no issues found , customer is moving and spoke to office about canceling membership. Scheduled next tune up date: