30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for willis, tx


Map of Willis TX
Mario S.

Mario S.


Job Checkin

System-main Approx Age of System: 8 Refrigerant Type- R410a Metering Device- TXV SP/HP:118/298 SLT/LLT:62/94 VSAT/LSAT- 46/102 Superheat/Subcool-16/7.6 Outdoor Entering Air Temp-78 Outdoor Fan FLA- 1.1 Compressor RLA/LRA-12.1/74 Contactor Voltage-28/220 Indoor Return Dry Bulb Temp-74 Supply Temp-56 Temperature Difference-18 Required Difference-16-22 Blower FLA- 3.2 Filter Sizes – 20x25x1 Changed Filters – Y (customer provided) Blew out drain line: N no blow out valve Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes-System is fully operational, filter was dirty and replaced. No other issues were visible, Scheduled next tune up date:Jan 21st 8-10