Job Checkin

Upon arrival performed a one system checking cooling. Checked indoor unit electrical, mechanical and safety components. Checked filter and customer said it was due in may to change out, filter looked good. Checked outdoor units electrical, mechanical and safety components as well as Freon levels. While testing the disconnect was able to turn it off and when I went to turn it back to the on position condenser wouldn’t come back on. System has a faulty disconnect and needs to be replaced. Because of colder temperatures covered condenser to raise pressures up. Pressures were reading low, system has lost about half its charge, refrigerant lines are a sealed circuit so Freon should not be escaping. recommended performing a leak search to determine where the leak is. Sent estimate over to replace disconnect, perform leak search and sent a price to warranty out the coil if we find a leak in the coil. Customer wanted to speak with office. After speaking with office Thomas wanted to move fo