Upon arrival found upstairs unit not cooling. Checked inside unit and found that the blower motor bearings are bad and blower motor locks up. Found that the filters were dirty and recommended changing. Also found that the low voltage fuse was blown on board. Traced low voltage short to some exposed wiring outside where wire was spliced. While checking outdoor unit noticed downstairs unit was frozen up. Inform homeowner that typically when a unit freezes up it’s low on Freon. System is 16yrs old and uses R-22 Freon. Recommended either perform a leak search on downstairs system or replacement due to R-22. I was unable to check pressures on upstairs system due to blower motor being bad. Explained to homeowner that we can repair upstairs system but system could be low on R-22 Freon as well. Emailed repair estimate and replacement estimate. Both systems are not cooling at this time.