1570 Old York Road
Abington, PA 19001
215-659-4343

Local Reviews
for cheltenham township, pa

Rated 5.0 out of 5 stars based on 21 customer reviews

Great service

He knew his job and was very polite.


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you, Sylvester & Gwen.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service


Response from Chud Air Conditioning & Heating:

5 stars, thank you Dan!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Paul came out and was through and quick and did a wonderful job with my heater. 5 stars.


Response from Chud Air Conditioning & Heating:

Nick, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Boiler and themostate check

Very helpful.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Paul was great and explained everything.


Response from Chud Air Conditioning & Heating:

5 stars, thank you Carole! The Chud team appreciates it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

On time and good service we’ll train in his field of work


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Terrell, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.


Response from Chud Air Conditioning & Heating:

Sylvester & Gwen, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service!


Response from Chud Air Conditioning & Heating:

Natasha, thank you for the 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Customer Service

Can’t say enough about the professionalism and excellent customer service I just experienced with CHUD. The technician was very professional as well and just a really nice guy. Thank you for your help this past week when our furnace ignitor cracked and left us with no heat.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Lisa, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

CHUD and their service tech

Called with a heating problem. Came out within an hour and a half the same day I called. Tech very punctual , polite and communicative. Would recommend CHUD to anyone. Have to wait for a part , but otherwise entire transaction was very good.


Response from Chud Air Conditioning & Heating:

5 stars, thank you Lisa!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Tech completed his visit and job professionally


Response from Chud Air Conditioning & Heating:

5 stars, thank you Wayne! The chud team appreciates it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Service

This was a call back based on previous fall maintenance check. There was immediate offer to come back to review.


Response from Chud Air Conditioning & Heating:

Barbara, thank you for leaving the 5 star review! We were happy to come back out and reconfirm everything is working properly with your system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chud Duct Cleaning

Good Job!


Response from Chud Air Conditioning & Heating:

5 stars, thank you Tom & Audrey!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great guy

Great guy!!!! Was early, polite, knew what he was doing. Will recommend him and your company !!!! Thank you !!!!!


Response from Chud Air Conditioning & Heating:

Martin, thank you for the kind words and 5 star review. The chud team appreciates it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service with helpful information!

Our AC broke during a heat spell. We received immediate attention, helpful explanations, and courteous customer service.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Tom! The team here at Chud appreciates it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for cheltenham township, pa

Thomas W.

Thomas W. Job Checkin

Performed preventative maintenance on a Lennox air handler. Model number: CBX32MV-048-230-6-06, serial number: 1612K05258. Upon arrival the unit was on. I adjusted the temperature on the thermostat so the unit would keep running. Went downstairs to the unit and watched it run. Removed the panel. Inspected the evaporator coil for any dust build up. Poured water into the condensate trap and watched it drain properly. Poured water into the condensate pump and watched it pump out properly. Checked the blower motor and fan for any dust build up. Homeowner recently replaced the 20x24x1 filter. Checked all electrical connected to make sure they were secure. Placed the panel back in the unit and watched it run. Went outside to the condenser and watched it run. Checked the coils for any dirt build up. Removed the panel and brushed out any spiderwebs. Checked the contactor and capacitor. Both are running within the manufacture’s specs. Took an amp draw of the fan, .83 amps. Took an amp draw for


Thomas W.

Thomas W. Job Checkin

Customer called due to no cold air blowing through the system. It is a Coleman, model number: TC4B6021SA, serial number: W1N8419823. Went downstairs to the unit, saw it running. Went outside to the condenser, saw it running. Hooked my gauges up and found the unit to be low on refrigerant. Added 3 pounds of 410a refrigerant to the system. Also added half a dye stick free of charge per RC. Let the system run for awhile. Pressures were good and got a temp split of 19°. Checked the evaporator for any freezing. Checked the pump to make sure it was pumping out properly. Took amp draws of the fan and compressor. Both running within manufacture’s specs. Checked filter, still good. System is running properly at this time. Will schedule a follow up to perform a leak inspection free of charge per RC. Add 3 pounds of 410a to help system run.


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Lennox AC system. Model # CX34-36B-6F-2 , serial #6014K01297 . Upon arrival the homeowner had the thermostat in the off position. I powered down the system at the furnace and removed the access panel. The evaporator coils are dirty on one the right side. I tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. The air filter was recently replaced by the homeowner size 20x25x1. The blower motor and blower wheel are both clean and in good condition. I checked all electrical connections to ensure that they are secure and in good condition. I re attached the access panels and powered the system back up. I called for ac and observed the system starting normally. The condenser coils are severely clogged and should be cleaned. The condenser amp draws are 9.12 for the compressor and .93 for the fan. The temperature split is at a 18° differential. After presenting my findings the hom


Paul T.

Paul T. Job Checkin

Came out today to perform a leak investigation on a Lennox ac system. Model #XC14-036-230-07, serial #5814L01440. Upon arrival the homeowner stated that he has not turned the air on with the exception of last night due to the cool weather. I called for ac and observed the system starting normally. I let the system run for about 20 minutes and I received a temperature split of 19°. I powered down the system and began the leak investigation using an electronic leak detector. I checked all brazed connections, condenser coil and evaporator coil. I was unable to find any leaks in the system today. After speaking with PA as a courtesy I added 1/4 stick of uv dye. Chud will return in 2-4 weeks to perform leak detection. No charge for today’s inspection. Paid for on 4/14/23


Amanda  F.

Amanda F. Job Checkin

Gathered photos and information in regards to homeowner remodeling bathroom. There is a 3” x 9” x 10’ piece of rectangular duct that needs to be raised for the new tub to fit. N/C, will follow up with pricing.


Shane A.

Shane A. Job Checkin

Ruud: M# ugph-10EAMER - S# Fd5d302f190211506 Replaced the fuel delivery and renovated the air movement system. Cycled unit on and off and checked operation. System is operating properly as per manufacturer specifications. This repair comes with: 5 Year Warranty for the repairs listed on this invoice 5 Year CCM Maintenance Membership


Matthew M.

Matthew M. Job Checkin

Completed Goodman air handler and daikon outdoor condenser installation. Adapted to all existing connections. Replaced thermostat with Honeywell T4. Outside added junction box, and 3 phase disconnect box. Replaced pad. Cycled and tested, system working properly at this time.


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Goodman AC system. Model #GSX140601KD, serial #2006201187. Upon arrival the system was set for heat so I powered down the thermostat. I powered the system down and removed the access panel. The evaporator coil’s are clean and in good condition. I tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. The homeowner has a Honeywell electronic air cleaner but is putting a 16x25x1 air filter inside. I checked all electrical connections to ensure that they are secure and in good condition. I re attached the access panels and powered the system back up. I called for AC and observed the system starting normally. The condenser coils are dirty but in fair condition. The condenser amp draws are 1.1 for the fan and 7.3 for the compressor. The temperature split is at 16° differential. I presented the homeowner with several different solutions to help the system in the home. The homeowne


Shane A.

Shane A. Job Checkin

Manufacturer Goodman Model # GSX160601FF Serial # 1908708748 Completed a preventative maintenance on a Goodman air handler newly installed. System is operating properly temperature split is 20 degrees. Performed a amperage readings on the blower motor condenser fan motor and compressor all are operating properly at this point. Changed out 20x24x1 filter and tested drain Manufacturer Fujitsu Model # AOU24RLB Serial # 000381 Also performed a maintenance on two mini split units. Cleaned washable filters did amp draws on the compressor and I also water tested the unit. All systems are operating properly at this point


Matthew M.

Matthew M. Job Checkin

Will have to return tomorrow to finish installation.


Paul T.

Paul T. Job Checkin

Came out today for a heating issue for a RUUD furnace. Model #ugph-10EAMER, serial #fd5d302f190211506. Upon arrival the homeowner stated that the could smell something burning through the vents. The thermostat was turned off when I arrived. I called for heat and observed the system starting normally. I let the system run and took an amp draw of the blower motor and got a reading of 6.1. This is a high amp draw for this system. I took a combustion analysis test and received the following readings, o2 is at 7.1% and the co level are at 47ppm. The system is 21 years old . I presented the homeowner with several solutions. The homeowner went with the platinum option. Chud will have to schedule a return visit for repair once parts are received.


Shane A.

Shane A. Job Checkin

Customers air is working. They called about a question if they can unplug their dehumidifier from their hvac unit. System is operating properly at this point. Manufacturer Goodman Model # CAPF3030C6DB Serial # 1408092529


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 3 bedroom single system home. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!


Paul T.

Paul T. Job Checkin

Came out today for a no AC call . Upon arrival I found the Lennox system calling for ac but it is extremely hot in the home. Model #XC14-036-230-07, serial #5814L01440 . The temperature split is currently at a 1° differential. I connected my gauges and found that the system is low on refrigerant approximately 4 lbs. the Merv filter is still good for another month and the Evaporator coil’s are clean and in good condition. I explained to the homeowner my findings and presented several solutions for his system. The homeowner went with the bronze option. I charged the system with 3lbs of 410-A and the system now has a temperature split with a 19° differential. The system should run for 1-2 weeks then Chud will return to perform a leak detection. Once the leak is found we can then order the proper part and perform the repair. Fill system with refrigerant per manufacturer specs. Return to perform leak investigation Repair leak after it is located allow 3-4 hrs- labor only.


Paul T.

Paul T. Job Checkin

Came out today for a heating issue. Found the Weil McLain boiler model # CGA-8 PIDN, cp #CP7926873. Upon inspection I found one room upstairs that had a runaway zone valve. The zone valve was left in the open position. I did close the zone valve so the room would not continue to heat. The boiler is on a constant loop and Chud powers down the system after every winter. Upon heating season Chud will return to turn it back on. Bill out per dispatch.