1570 Old York Road
Abington, PA 19001
215-659-4343

Job Locations
for norristown, pa


Map of Norristown PA
Frank B.

Frank B.


Job Checkin

Performed preventative maintenance for 2 zone boiler system. Inspected all the electrical components. Confirmed proper high and low voltages. Cleaned the burners, burner assembly and burner compartment. Found the electronic damper not functioning but in manual mode so the boiler still functioning. Found the pressure/temperature not reading properly due to water infiltration as well as the auto fill which is meant to maintain the set water pressure without manually filling the system. System is 18-19 years old and has plenty of signs of rust/oxidation. System is fully operational but only in fair condition. In its current state even though fully functioning it possesses a failure risk. Recommend speaking with our comfort advisor to at least go over options for boiler , ac only and water heater even if not in the position to replace at this time. Performed a combustion analysis on the boiler. System is operating at 78.9% efficiency with a CO level of 32ppm. System is in fair condition an