Performed preventative maintenance for gas furnace. Cleaned the burners, flame sensor, inducer port and burner box. Inspected all the electrical components. Tested the amp draw from the blower and inducer. Both are operating within the manufacturer spec. Customer didn't need the Merv11 filter replaced yet. It still fairly clean. Performed a combustion analysis on the furnace. System is operating at 83% efficiency with a CO level of 17ppm. Customer also has a bypass humidifier. Humidifier had issues last year so the water panel is still in good shape. Next season the water panel will need to be replaced. Inspected the gas piping. System had a 53° temp rise. System is operating properly at this time.