Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Checked filter. Humidity in home is very high: 76%. Compressor: 12.1A . Condenser fan: 1.7A . Blower: adj. ML:3.5A . ambient: 69 . liquid line: 81. suction line: 62. metering device: piston . Suction pressure: 59(34) . head pressure: 115(89) . Return air: 72.5 . supply air: 58 . wet bulb: 66 . SH: T+5. Work suggested: Recommend running air-conditioner even if nobody is home to avoid high humidity damage and mold growth. Recommend connecting dehumidifier in basement and set up over the drain to run without having to empty the bucket. Recommend keeping basement windows closed.