Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level: low! Perform leak search on system and found evaporator coil leaking. Will need new evaporator coil. Split and washed condenser coil. Work suggested: replace evaporator coil: $1479. Need to check with manufacturer on possible parts warranty.