Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. Checked drain. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 6.3/6.7A. Inducer:.85/1.75A . Gas pressure: 4.0/9.8 inches water column. Temperature rise: 38 . Supply: stg1 114 . Return: 76 . Humidifier Service declined. Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Checked filter. .45” drop across 3M pleated filter. Compressor: 22.5A. Condenser fan: 1.4A . Blower: 7.8A. h .ambient: 71 .liquid line:88 .suction line: 57 .metering device: piston. Suction pressure: 65(38) .head pressure: 192(98).