Local Reviews
for des peres, mo

Rated 4.9 out of 5 stars based on 34 customer reviews

Annual Furnace System Servicing and Review

Service was excellent. On-time, quietly competent and quickly done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful Service

Did a great job diagnosing the problem and performing the necessary fix.

  • Overall Experience
  • Quality
  • Price
  • Convenience

When he arrived he diagnosed the problem within minutes, very Satisfied

We won't have the A/C repaired totally until Roger can secure a part from Carrier, so far we are very pleased with the fine service we are receiving from CLASSIC AIR CARE! We appreciate the temporary fix that Roger performed!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional, Efficient Service with a Smile

Moving Day. Frigid temperatures. No heat. We were in a jam and Classic Aire Care saved the day! We are so thankful for the professional and speedy attention to our furnace mishap. With Sean's help, we were able to get back on (a much warmer) track to move into our new home. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service. Always prompt and courteous.

they don't hesitate to come back free of charge after a service call if something isn't right.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very thorough and professional - excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job and friendly service

As it turned out we had an area of common interest (hobby) which added some friendly conversation while not interfering with the repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Brian is excellent and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional

courteous, competent, thourough

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt service

Experienced techs provide help on questions

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent timely service.

I am happy with Classic Aire Care's service. They were able to provide same day service, all the employees were friendly and customer oriented and the price was reasonable. I will definitely continue to use them in the future.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service as Always

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional

Polite, professional, technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for des peres, mo

John M.

John M. Job Checkin

Found furnace locked out: 2flashes. Found flame current very weak. Cleaned flame sensor and tested: 2.2uA. Found blower dropped out apoun engaging stage 2 heat!! Corrected wiring of blower. Inducer: 0.32/1.04A. Blower: 3.9/5.1A. Checked temperature rise: 30/48. Checked draft: 0.04”. Does not appear to have proper flue liner in masonry chimney. Suggestions: Furnace is about 22 years old. replace furnace soon. Recommend installing new flue liner to protect chimney.


John M.

John M. Job Checkin

Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked drain. Checked voltage & amp draw of motors. Blower: 1.3A/4.9A . Inducer: 0.2/0.62A . Gas pressure: -/1.7/3.5 inches water column. Temperature rise: H:70 . Clean and check humidifier, replace pad, checked water flow and drain. The humidifier pads that we delivered are the wrong size . I am returning three #12 humidifier pads to the office . need to refund customer $49.


John M.

John M. Job Checkin

I removed blower door to find flashing code 4: open primary limit. There was no voltage to limit and inducer would periodically turn on. I replaced furnace control board, including new igniter. Tested operation. Inducer: .37 A. Blower: 4.0 A.


Jeff K.

Jeff K. Job Checkin

Fall maintenance today for the furnace!


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 4.8A. Inducer: 1.18A. Gas pressure: 3.5 inches water column. Temperature rise: 54 . Supply: 128. Return: 74 . Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Compressor: 8.2A . Condenser fan: 0.7A. Blower: 5.4A . ambient: 56 . liquid line: 62. suction line: 44 . metering device: TXV . Return air: 71 . supply air: 50.


Roger H.

Roger H. Job Checkin

Serviced furnaces and humidifiers


John M.

John M. Job Checkin

I removed motor module from murder. I’m doubt motor windings: OK. Installed new module and adapter ring and harness. Tested operation and found Motor would not run. Blower wheel rocks back and forth. I tested wiring harness continuity. I put old motor module back on for temporary cooling. Need to return with another replacement module. Work suggested: need to call Carrier and double check part numbers. Need to order New motor module. Call customer ASAP when availability is known.


Roger H.

Roger H. Job Checkin

No cooling by passed blower module till part is replaced


Roger H.

Roger H. Job Checkin

Serviced air conditioner and replaced filter


Roger H.

Roger H. Job Checkin

Repaired short in wiring..on furnace


Jeff K.

Jeff K. Job Checkin

AC maintenance! Replace run capacitor for blower and dual capacitor for condenser


Roger H.

Roger H. Job Checkin

Replaced bad pressure switch


Roger H.

Roger H. Job Checkin

Replaced Lennox uv bulb


Sean K.

Sean K. Job Checkin

Clena and chec


Sean K.

Sean K. Job Checkin

No heat, clogged pressure switch