Would highly recommend you.
Tom is always a pleasure to have as our geothermal tech. Very pleasant, informative and professional.
Tom is always courteous, friendly and on-time. Very skilled in his work.
Did a great job diagnosing and fixing our heater problem. Showed up and finished quickly. very professional and informative.
No after hours support? Call us back after the several calls with no person answering the phone!
Tom Scheureman is the very best I have ever worked with on my system. Fast, knowledgeable, polite and efficient! Came within 5 hours of my emergency call. Office staff was quite helpful also! Especially Dianna and Tressa.
Pumped down system. Removed and replaced evaporator coil. Pressurize and leak check connections. Evacuate low side and topped off Freon level. Compressor:9.3A . Condenser fan: 0.84A. ambient: 83. liquid line: 90 . suction line: 54 metering device: TXV . Suction pressure:119(40) . head pressure: 318(99). Return air: 69.
Cleaned and checked 2 air conditioners. Checked drains. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon levels. Cleaned condenser coils. Checked filters. Second floor system: Found dual run capacitor weak: 28%low, fan side. Declined. Suction line 62, superheat 27. Moved sensing bulb. Compressor: 9.7A . Condenser fan: 0.76A. Blower: 4.4A, 1050 . ambient: 77 . Subcooling: 11-12. Superheat: 20. suction line: 57 . metering device: TXV . Suction pressure: 112(37) . head pressure: 310. Return air: 72. supply air: 50 . wet bulb: 59. First floor system: Compressor: 9.1A Condenser fan: 1.0A . Blower: 4.0A, 1250. ambient: 77 . liquid line: 83 . suction line: 47. metering device: piston . wet bulb: 59 . Work suggested: Second floor system: replace dual capacitor: $190. Customer declined repair. Interested in replacing unit.
Maintenance on Rheem air conditioner with Ameren rebate
Maintenance on air conditioner with Ameren rebate
Maintenance on Lennox air conditioner with Ameren rebate
Maintenance on Rheem air conditioner with Ameren rebate
Maintenance on 2 Carrier air conditioners
Armstrong air leak checked evap coil measured duct
Cleaned & checked 2 gas furnaces. Inspected heat exchanger & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Clean and check 2 humidifiers, replace pads, checked water flow and drains. First floor system: Blower: 1.7/3.0A. Inducer:.08/.23A . Gas pressure: 1.92/3.7 inches water column. Second floor system: Blower: 1.6/2.55 . Inducer: .08/.24A . Gas pressure: 1.9/3.7 inches water column.