1276 N. Warson
St. Louis, MO 63132
(314) 352-1111

Local Reviews
for richmond heights, mo

Rated 4.9 out of 5 stars based on 19 customer reviews

wonderful service, nice servicemen

all great

  • Overall Experience
  • Quality
  • Price
  • Convenience

review

  • Overall Experience
  • Quality
  • Price
  • Convenience

Arrived on time, efficient, fixed the problem.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent job as usual

great company

  • Overall Experience
  • Quality
  • Price
  • Convenience

I trust this service

We have been having our system serviced with this company for many, many years.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

The man who came to our house did a great job, and was patient w our questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!!

Tom was very efficient in diagnosing the problem with our furnace, and was extremely efficient in his recommended repairs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgeable

Showed me the situation with the furnace, explained and answered all my questions, polite.

  • Overall Experience
  • Quality
  • Price
  • Convenience

On time, never stopped working, answered all questions.

Joe was wonderful. It was great that he put shoe covers on without being asked.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Complete Professional Service

Serviceman - Joe was excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work, as usual.

Roger is a fine professional. I usually request him for any service work. There are probably other fine technicians, but I know he's good.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing!

Our heating repair man was amazing. He diagnosed the problem immediately, and also resolved some other minor aggravating issues.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service, Josh was just GREAT!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for richmond heights, mo

John M.

John M. Job Checkin

Vacant house. Found main pump leaking water from bearing assembly. Has bad seal. Needs new pump. Suggestions: replace main pump: $1484. Customer does not want repair done at this time. Call customer for cc number.


John M.

John M. Job Checkin

Wine room is maintaining 55 degrees. Waited for storm to pass. Installed low-ambient controls for Wine room condensing unit on roof. Also installed crankcase heater on compressor. Set cut-in and cut-out pressures. Tested operation.


John M.

John M. Job Checkin

Complaint: Wine cooler not keeping temperature. Showing AL. Overnight low was six below. I turned on unit and found pile of ice forming at evaporator and let. Appears low on Freon. I went up to roof. I blocked outdoor coil to simulate warmer day. Conditions with coil blocked: amp draw: 7.1A. Liquid line: 58. Suction line: 45. Unit was not able to keep up with extreme cold ambient temperature. Also, system may be low on Freon or have a Freon restriction. Cannot tell with current conditions. Suggestions: system may need a low-ambient kit to keep pressure is high enough during extreme cold weather. Need to check with manu. about low ambient kit recommendations. Freon pressures need to be checked under warmer conditions. Over 60 Fahrenheit.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Found basement pressure negative (-.005 inches water column) due to leaks in return-air ducting and return air vents blocked by curtains and dirt. Moved curtains. Adjust Blower: 3.0A . Inducer: 1.0A . Adjust Gas pressure: 3.6 inches water column. Temperature rise:48 . Supply: 115 . Return: 67. Basement: <-.001”. Suggestions: clean return air vents and keep curtains away from return air vents. Humidifier: $716


John M.

John M. Job Checkin

Work Done: Cleaned & checked 2 gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Checked drains. Checked condensate pump. First floor: replaced air cleaner media. Clean and check 2 humidifiers, replace pads, checked water flow and drains. Second floor system: Check temperature rise. Min: 65. Stack: 88. High: 63. Stack: 108. Total amps:9.5A. Inducer: 0.64A.


John M.

John M. Job Checkin

Cleaned and checked gas boiler. Inspected and cleaned heat exchanger. Checked flu piping and draft. Cleaned burners, pilot, and flame sensor. Checked voltage and amp draw of pump. Filled system. Bleed air from system. Found high expansion rate. 6.5:1. Expansion tank is too full. Suggestions: replaced thermostat batteries. Drain expansion tank: $100-$300 if serviceable. depending on fittings/piping coming loose for service and amount of draining system requires. If new expansion tank is required, could cost: $1000.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 1.5/2.6A . Inducer: 0.07/0.24A . Gas pressure: 1.9/3.7 inches water column. Temperature rise: 48/55 . Supply: 123/130 . Return:75 .


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 5.1A . Inducer: 0.55A . Gas pressure: 1.9 inches water column. Temperature rise: 48 . Supply:119 . Return: 71 .


Roger H.

Roger H. Job Checkin

Checked out water leak at furnace


Roger H.

Roger H. Job Checkin

Serviced ac..found leak in evaporater coil..replacing under part warranty only


Roger H.

Roger H. Job Checkin

Replaced warranty sensor on ac


John M.

John M. Job Checkin

Customer described Icing of coil symptoms. Found superheat creeping to 30+. I relocated thermostatic expansion valve bulb and retested. Superheat regulating normal now. Compressor: 5.4A .Condenser fan: 0.32A . Blower: 700 cfm .ambient: 76.liquid line:77 .suction line:48 .metering device: TXV . Suction pressure: 103(33) .head pressure: 279(91). Thermostat: 71.


John M.

John M. Job Checkin

Work Done: Cleaned and checked 2 air conditioners. Checked drains. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon levels. Cleaned condenser coils. Second floor system: installed PURE-AIR maintenance kit for air purification system. Compressor: 9.5A .Condenser fan: .78A . Blower: 1600 .ambient: 68 .liquid line: 68.suction line: 57 .metering device: TXV . Suction pressure: 101(32). First floor system: Found blower run capacitor too weak. Replaced capacitor and tested amp draw of 3/4hp blower. Compressor: 12.3A .Condenser fan: 1.4A Blower: 9.1A.ambient: 76. metering device: TXV . Suction pressure: 55-62. Return air: 67.supply air:49-52 .wet bulb: 59 . SC: 3-10. SH: 16-22. (Noncond)


Roger H.

Roger H. Job Checkin

Replaced filters


John M.

John M. Job Checkin

Work Done: Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Checked electronic air cleaner: very dirty and blocking air flow. Compressor: 13A.Condenser fan: 1.45A . Blower: 5.7A, mh.ambient: 60 .liquid line: 66 .suction line: 35.metering device: TXV . Return air:65.5 .supply air: 44 .wet bulb: 55 . Work suggested: customer plans to clean air cleaner.