1276 N. Warson
St. Louis, MO 63132
(314) 352-1111

Local Reviews
for webster groves, mo

Rated 4.9 out of 5 stars based on 58 customer reviews

Great service

John Murphy does a great job with inspecting and cleaning furnace.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

The guys showed up right on time and were very courteous. They recommended some minor improvements, made one of them and replaced my filter.

  • Overall Experience
  • Quality
  • Price
  • Convenience

prompt and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Rapid response

Rapid response, friendly and efficient service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service with know-how!

Jeff did a great job and had great familiarity with our furnace even though it is not a new unit! He did a great job inspecting, maintaining and cleaning the furnace. Thanks Jeff!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Personable service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service Appointment

  • Overall Experience
  • Quality
  • Price
  • Convenience

Well Done

Very thorough, competent job done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

quality service

On time, efficient, neat and tidy. set up next apt for AC....now it is already on my calendar.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Price is Too High

John Murphy did a great job and is easy to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Failure to call landlord before performing service

Mr. Patrick Ortmann should have called me before performing the service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Speedy service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service, Excellent Technician

Corey was helpful, thorough, good at explaining what was being done and what could be done. He was pleasant and cheerful. A totally enjoyable experience, and it is noticeably helpful (increased airflow) already.

  • Overall Experience
  • Quality
  • Price
  • Convenience

most thorough air conditioner service

I was so impressed with the service I received. The service representative was so thorough and professional. I was so impressed that I signed up for their service contract,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for webster groves, mo

John M.

John M. Job Checkin

Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked drain. Blew out PVC drain. Checked filter. Clean and check humidifier, replace pad, checked water flow and drain. Suggestions: Need to add humidifier to maintenance plan at next renewal.


John M.

John M. Job Checkin

I found flame sensor current to low. Also, furnace is in need of cleaning. Replaced flame sensor. Tested operation. Temperature rise very high. I replaced customer’s air filter. Checked temperature rise. 56. I found return air duct is open where it is against the wall!! Apparently had a return air vent on the other side of the wall. wall Has been closed off! System is relying on only the return air duct that comes down from the attic. This only remaining ducting is too small for this equipment. Return duct pressure: -.35 inches water column. Suggestions: need to schedule first visit for maintenance plan purchased today. Customer would like a price to replace the furnace and to correct the duct issues.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Humidifier not used. Blower: 1.8/5.7A . Inducer: 0.55/1.3A . Gas pressure: 1.9 inches water column. Temperature rise: 52 . Supply: 118. Return: 66.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Replaced air filter. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 2.6/3.7A . Inducer: 0.11/0.24A . Adj Gas pressure: 2.0/3.7inches water column. Temperature rise: 51/59 . Supply: 128/120 . Return: 69 .


Jeff K.

Jeff K. Job Checkin

No heat—replaced warranty gas valve


Jeff K.

Jeff K. Job Checkin

Fall maintenance today for the furnace!


Roger H.

Roger H. Job Checkin

Serviced furnace and installed uv light


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Back-flushed condenser coil with Water-Saber. Compressor: 8.6A. Condenser fan: 1.15A . Blower: 4.6A. ambient: 69 . liquid line: 76. suction line: 53 . metering device: TXV . Return air: 71 . supply air: 53 . Replaced air cleaner media.


John M.

John M. Job Checkin

I found disconnect pull-out switch missing!! I turned off the breaker at main panel, but still had voltage to one leg! Check voltage at circuit breaker in panel: no voltage, but still has voltage at one leg outside! I wired around missing pull out switch for testing. I found condenser fan motor bad! Shorted windings. Also, compressor run capacitor is bad. Open circuit. Also found system very low on Freon. Air-conditioner is 29 years old. Uses older type of Freon. Work suggested: recommend replacing air conditioner.


John M.

John M. Job Checkin

Returned after 6 o’clock in the evening to replace GFCI outlet. System had shut off again due to condensate pump float safety. Condensate pump was temporarily plugged into an outlet controlled by the light switch!! Installed new outlet. Tested condensate pump. Thermostat should be OK.


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Found wire connection overheating at capacitor. Found superheat off target. Also, Schrader caps missing. Back-flushed condenser coil with Water-Saber. I topped off Freon(410A) level and installed new brass caps. Compressor:11.6A . Condenser fan: 0.68A . Blower: 5.8A . ambient: 81 . suction line: 38. metering device: piston . Suction pressure: 114(38). Return air: 67.5 . supply air: 50.5. wet bulb:59 . Work suggested: remove box setting on the drain line. Freon leak search: $189. Freon leak repair: $?


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced air filter. Compressor: 13.9A.Condenser fan: 0.62A . Blower: 4.5Aambient: 84 .liquid line: 101.suction line: 38. metering device: Piston . Return air: 70.supply air: 51.5 .wet bulb:58.5 .


Jeff K.

Jeff K. Job Checkin

Spring maintenance for ac system!


Tom S.

Tom S. Job Checkin

Maintenance on Lennox air conditioner replaced air filter


Jeff K.

Jeff K. Job Checkin

Service call no cool—bad dual capacitor