Job Checkin

Basement system: replaced blower motor. Tested cooling operation. Compressor: 16.2A . Condenser fan: 1.52A . Blower: L. ambient: 80 . liquid line: 86. suction line: 51. metering device: TXV. First floor system: reclaimed 410A Freon. 13lbs. Replaced grounded compressor. Pressure tested connections @285psi. Evacuate system and recharge. Replaced air filter. Compressor:17A. Condenser fan: 1.25A . Blower: 1750 . ambient: 86. liquid line: 95 . suction line: 54 . metering device: TXV Suction pressure: 125(43) . head pressure: 330(103) . Second floor system: Replaced air filter. Master bedroom system: Replaced thermostat batteries. Work suggested: Need to schedule first clean and check for new PMA.