Completed custom ductwork installation at new construction in Houston. Client had hired another company initially, but their standard ductwork design wasn't adequate for the unique floorplan. Our team fabricated 17 custom sheet metal pieces to create proper airflow throughout the 3,200 sq ft home. Focused particularly on the master suite extension, which required careful planning to ensure balanced temperatures. Utilized our 24-gauge galvanized steel throughout for durability and noise reduction. Incorporated specialized dampers for zone control as requested by homeowner. All seams properly sealed with mastic (not tape) for superior leakage prevention. Pressure tested system upon completion - achieved 3% leakage rate, well below the 6% industry standard. Builder was impressed with the clean installation and minimal space requirements of our design. System now delivers balanced airflow to all rooms despite the challenging layout.