5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for buford, ga

Rated 4.8 out of 5 stars based on 193 customer reviews

Thorough

Was helpful with all 3 systems.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Timely service!

Knowledgeable Technician

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Fast service

Fast and quick.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Service was exceiient

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

Vu is Great!!!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Excellent service and knowledgeable

Technician was skilled, knowledgeable, friendly and respectful. Call was for a/c not working and he efficiently identified the problem, ordered the part and provided immediate cooling relief. Would highly recommend.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Quick same day service, even came early

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for buford, ga

Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Reece W.

Reece W. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Installed hard start kits Andrew surge protection for both condensers. Installed two forms of water safety for the upstairs system. Will return to replace the upstairs coil.


Steve I.

Steve I. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Signed customer up for Comfort Club membership.


Vu T.

Vu T. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jordan R.

Jordan R. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Reece W.

Reece W. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Changed filter. Tested mechanical and electrical components, all in good shape. Chemically washed condenser coil. The system is cooling normally at this time.


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found filter very clogged and dirty. Changed the filter system is cooling. The system is 16 years old and the compressor is working with amps higher than manufacture spec. Recommend replacing the system. Having Garrett to come out and give a quote.


Vu T.

Vu T. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Find outdoor system fan motor fail. Find system 16-year-old with damage/burnt contactor, weak capacitor. Replace motor, install hard start kit, replace contactor and capacitor. Sign up 1 Comfort club membership plan. Change filter, check the drain and clean a/c coil. Recharge system to manufacturer spec. System missing water safety in the attic. Suggest installing water protection. Install inline water protection and over-float protection.


Vu T.

Vu T. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Check and find upstairs system not cooling properly. Find system miss match and not size properly. Find outdoor unit 3 Ton and indoor coil only 2.5Ton. System not charge properly and can have liquid back pressure and damage compressor or over heat compressor. Need to replace upstairs evaporator coil with 3 Ton coil for proper match up per manufacturer spec. Downstairs also have to same problem. 5 Ton system and only have 4 Ton capacity coil. System not match properly. Need to replace both coil for proper cooling and match up.


Vu T.

Vu T. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Find burnt furnace power switch. System low on charge and missing valve cap. The system doesn't have a hard start kit. Install hard start kit, recharge system and add 2 valve cap. Replace furnace power switch in the attic. System operating at this time.


Jon F.

Jon F. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Piston at coil was not tightened all the way leaking refrigerant. Also, the filter was very dirty from recent construction. Changed filter tightened piston and filled back up with refrigerant. Sugared is cooling properly.


Steve I.

Steve I. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Found systems emergency drain pan full of water. Cleaned water and cleared drain line. Checked operation. Found pressures good. Checked zone dampers, made sure both were moving freely. Made sure System was working good with one zone working. Fixed a burnt area on the return duct from torches. Replaced filter. Suspect the drain was the problem.


Reece W.

Reece W. Job Checkin

Complete 3 system a/c repair and preventative maintenance check. 2 systems up for renewal, third system prepaid under install. Changed filters. Tested mechanical and electrical components, all in good shape. Chemically washed condenser coils. Systems are cooling at this time.


Steve I.

Steve I. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Quoted customer various options to replace the upstairs and downstairs systems. Included in estimate was to upgrade the zone system for the downstairs system.


Jon F.

Jon F. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. The main level running well. Changed filter recommend drain pan float switch and inline float switch. Bonus room unit leaking at evap coil recommend replacing the coil and adding drain pan float switch and inline float switch.