5322 Palmero Ct
Buford, GA 30518
770-203-1600

Local Reviews
for sugar hill, ga

Rated 5.0 out of 5 stars based on 10 customer reviews

Great Service

Always great service. Technician is very thorough with explaining what's needed for efficiency. Would recommend to everyone.


Response from Comfort Control Heating & Air:

Thank you, Maria!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good dependable service

Good solid service, only issue was that he wore his inside shoe covers outside to his truck to get a new filter. I asked him to change his covers which he did when he returned which was no problem.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Showed up on time. Great service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

awesome and fast

once again Ta Kim did a awesome job and Im proud to say he is a valued asset to your company. Please always send me him, he is very happy-go-lucky and explains everything that needs to be done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!!

Good guy, good service, thanks!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Service, polite technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

well pleased with service, and service representative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast service!

Technicians called 30 minutes before arriving as promised. They arrived ver early in the 2 hour time slot. Both were friendly, professional and efficient. They completed the repairs in under one hour at a reasonable cost. I have been happy with all the work they have done for me over the years.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sugar hill, ga

Reece W.

Reece W. Job Checkin

Found weak flame safety sensor. Replaced sensor and system is heating at this time. Part was under warranty so charged for labor.


Reece W.

Reece W. Job Checkin

1 furnace tune up complete. Changed filter. Tested mechanical and electrical components, all in good shape. Recommend surge protection to protect furnace from power surges. System is operating normal at this time.


Reece W.

Reece W. Job Checkin

Replaced 3/4 hp motor with new 20 uf blower motor controller. Replaced ignition system and flame safety system. Thermostat broke while I was trying to replace batteries so I replaced thermostat free of charge. System is heating at this time.


Reece W.

Reece W. Job Checkin

Found bad blower motor. Found worn, but functional, ignition system. Found flame safety sending very weak microamps to control board. Recommend replacing furnace. Applied for financing but was denied. Customer will call home insurance about system.


Reece W.

Reece W. Job Checkin

1 furnace pm check complete. Found air cleaner door (Aprilaire model 5000) not functioning. Tested mechanical and electrical components, all in good shape. Combustion has good readings. System heating normal at this time. Recommend more insulation for improved comfort and efficiency.


Seth D.

Seth D. Job Checkin

Responded to no heat call. Turned nest thermostat temp up 2 degrees and unit kicked on. Cycled furnace 4 times and found no issue.


Seth D.

Seth D. Job Checkin

Drain line line ran into vent because original drain line was clogged. This form of draining the pvc from the evaporator coil is used in many applications and sometimes necessary although against code. The current set up for draining will work and poses no water concerns. If drain line is tapped into auxiliary drain it will have to eventually be ran back into flu pipe or ran outside separately because it will drain from the soffit.


Reece W.

Reece W. Job Checkin

1 furnace pm check complete. Changed filter. Found combustion removal motor running rough, it could fail at any time. Dusted out furnace cabinet and cleared barometric tubing. Found worn ignition system and dirty blower wheel. Recommend upgrading furnace instead of repairs based on age and cost of repair.


Reece W.

Reece W. Job Checkin

1 furnace maintenance check complete. Changed filter. Found combustion removal motor running rough, it could fail at any time. Dusted out furnace cabinet and cleared barometric tubing. Found worn ignition system and dirty blower wheel. Recommend upgrading furnace instead of repairs based on age and cost of repair.


Reece W.

Reece W. Job Checkin

1 furnace pm check complete. Changed filter. Found combustion removal motor running rough, it could fail at any time. Dusted out furnace cabinet and cleared barometric tubing. Found worn ignition system and dirty blower wheel. Recommend upgrading furnace instead of repairs based on age and cost of repair.


Reece W.

Reece W. Job Checkin

1 furnace tune up complete. Found furnace not operating due to weak flame safety. Found weak blower motor controller and worn ignition system as well. Recommend repairs. Left customer with replacement filter. Recommend more insulation for increased efficiency and comfort. Recommend upgrading thermostat to a newer, more reliable thermostat. Replaced flame safety, ignition system, blower motor controller and recalibrated furnace for improved efficiency. System is heating at this time. Customer upgraded tune up to maintenance plan. Customer used $25 off coupon.


Paul C.

Paul C. Job Checkin

Furnace was turning off prematurely due to a faulty flame safety sensor. The sensor was replaced and the furnace is currently heating.


Vu T.

Vu T. Job Checkin

No heat warranty service call. Check and find heating system operating normally with worn and weak flame sensor. Need to replace flame sensor. Find thermostat also not holding programs properly and reset itself. Suggest upgrading tstat for better control. Find house have 2 level with open floor plan causing heat to rise upstairs and making upstairs hotter than the lower level. System operating at this time. Give customer estimate to repair flame sensor and upgrade tstat. Customer wants to wait and call us back later. Waive service fee due to warranty call back.


j.haney1320@gmail.com

j.haney1320@gmail.com Job Checkin

New 2.5 ton Goodman air conditioning system New outside pad 10 year parts and 2 year labor warranty


Phillip S.

Phillip S. Job Checkin

Completed maintnenace on furnace. Changed air cleaner in crawl space. Everything operating normal at this time.