Found system with plugged drain line leaking water Unit from upstairs leaking water from secondary indicating main primary drain line plugged. unplug drain line. Perform further diagnostic on unit found unit almost void of refrigerant added some refrigerant to determine if leak is visible found leak at indoor event coil recommend replacing indoor eve app coil and installing proper piston to match outdoor unit this will allow half the system to be replaced if you ever have to replace the outdoor unit All you will have to do is replace change piston in indoor unit to match new outdoor unit. Work done today Unplug drain line, charged system, leak search