Performed tune up maintenance contract. Turned system on from thermostat and unit kicked right on. Inspected unit for cleanliness and proper operation Unit is leaking water into the blower compartment and out of the doors, Blower compartment is covered in mold and debris. Blower wheel is caked in dirt and debris. Inspected all electrical connections. Circuit board is burnt and a relay had been put in place of that Burt function this is a temporary fix not a permanent one and should be addressed. Inspected blower motor and capacitor. Capacitor is within spec. Motor pulling 2 amps Filter is clean Condensate is disconnected. Need to be addressed. Do not have a proper temperature split. Unit is barley cooling the home, Evap coil is impacted with debris. Inspected condenser. Inspected unit for cleanliness and proper operation. Condenser coil is completely impacted with debris. Inspected compressor, have a amp draw of 16.3 amps Condenser fan motor pulling higher than spec. Capacitor