Main floor system is extremely low on R22 refrigerant. Saturation temp in indoor coil is 6*. Superheat is 64* Factory charge on unit is 10 lbs with an additional 3 lbs to account for line length and evaporator. Homeowner request quote to replace coils. Furnace is 7 years old and may be compatible with some cooling equipment.