Returned today to replace condensate pump on newly installed 2025 Rheem.Upon arrival removed malfunctioning condensate pump then installed new condensate pump after installation tested operation of condensate pump confirming its operation. Completed maintenance on system missed on previous visit performed a single system cooling maintenance on a 2005 Goodman the ODT is 80°.Tested overall operation of equipment confirming the indoor & outdoor equipment was both fully operational.The filter 20x25x2 was discolored and clogged the filter was replaced on this visit.Blower motor was fully operational not showing any signs of being intermittent or dropping out.Capacitor was tested confirming it was in specifications.Blower wheel was inspected finding it to be dirty when a blower wheel gets dirty it minimizes the efficiency of equipment along with places a strain on equipment and parts which shortens the lifespan of both a quote has been provided to clean blower wheel.Indoor evaporator coil w