Performed a two system heating maintenance on two 2009 Gibson the ODT 60°Tested overall operation of equipment confirming the indoor equipment was operational.Once operation was Confimred began diagnostic on the indoor equipment the media filters were slightly used but not discolored or clogged the filter was not replaced on this visit. Blower motor was fully operational not showing any signs of being intermittent or dropping out.Capacitor was tested finding them to be out of specifications which is adding strain to blower motor along with if worsened can cause loss of functionality a quote has been provided to replace capacitors.Blower wheel was inspected finding it to be dirty when a blower wheel gets dirty it minimizes the efficiency of equipment along with places a strain on equipment and parts which shortens the lifespan of both a quote has been provided to clean blower wheel.Inspected indoor evaporator coil finding it to be dirty when a indoor evaporator coil gets dirty it minimi