Quoted new furnace and air conditioner


Cody C.

Cody C. Job Checkin

DCM1: Heat complete, replaced (1)16x25x1 filter. System is fully functional and is operating within manufacturer specifications at this time, heat maintenance checklist attached.


Rob  S.

Rob S. Job Checkin

Replaced ambient outdoor temp sensor on outdoor unit. Initially system was reporting an outdoor ambient fault code, code cleared immediately upon installation of new sensor No faults currently reporting


Keith D.

Keith D. Job Checkin

Need to work up estimate


Brad  N.

Brad N. Job Checkin

DCM1 service 2 of 2 Heat: Changed (1) 16x25x1 filter, Performed Heating Maintenance Per Checklist, homeowner mentioned that he had colder rooms with low air flow, found that the supply side of the duct work is in very poor condition, falling apart, laying on the ground , and not connected properly or sealed, appears to be oversized for the equipment that is installed at this time, recommend having a Comfort Advisor Come out and look at ducting and give Options.


Rob  S.

Rob S. Job Checkin

DCM1 complete; Heat; (1) F16251 replaced. System is fully functional. All components are operating within manufacturer specifications. Gas pressure and temperature rises are within design tolerances. Heat checklist attached.


Rob  S.

Rob S. Job Checkin

Mitsubishi mini split system reporting faults Both head units reporting 6 flash fault ; outdoor thermistor fault Outdoor unit reporting 5 flash fault ; outdoor ambient thermistor, outdoor heat exchanger thermistor, defrost thermistor. Identified failed outdoor ambient thermistor


Rob  S.

Rob S. Job Checkin

DCM1: Heat complete, checked filter (1) 16x25x4, system is fully functional and operating within manufacturer specifications at this time, heat maintenance checklist attached below.


Cody C.

Cody C. Job Checkin

DCM1; Heat completed, filter check (1) 16x25x4, system is operating within manufacturer design at this time. Below is completed heat maintenance checklist.


Rob  S.

Rob S. Job Checkin

DCM1 complete heat (F16251) replaced, system is fully functional all components are operating with in manufacture specifications gas pressures and temperature rise are with in designed parameters. Heat checklist attached.


Rob  S.

Rob S. Job Checkin

DCM2 unable to complete; (2) F20251 and (4) F20252 replaced. A35 belt replaced. Building has a rodent infestation. Identified locations that looked like exterior lining of ducts had been chewed and a location were insulation has been chewed. There is probably a combined 20 feet of ductwork above the ceiling. When you move a ceiling tile, rat excrement falls out of the ceiling, every time. Recommend Comfort Specialist Send photos to Lynn Brown, office manage. Email listed in contacts


Brad  N.

Brad N. Job Checkin

DCM2 :Service 2 of 2 ;Heat, Checked (2) 16x25x4, Performed Heating Maintenance Per Checklist, systems are running at this time.


Brad  N.

Brad N. Job Checkin

Homeowner had a question about her water heater, she has a heat exchanger plumbed into her outdoor unit where the discharge line goes to a heat exchanger that assists in heating water for the home, and wanted to know if it needed to be removed or could it stay.


Brad  N.

Brad N. Job Checkin

No a/c call, thermostat was giving code for suction line temp sensor not reading, found that the sensor was open internal, with homeowners permission went and picked up sensor and replaced checked operation, psi 126/286, SH18, SC8, system is running at this time.


Brad  N.

Brad N. Job Checkin

DCM1 :Service 2 of 2, AC, Checked (1)16x25x1 filter it looked brand new left filter for homeowner, Performed Cooling Maintenance Per Checklist system is running at this time.