2 Tartan Ct
Conroe, TX 77301
832-458-0642

Job Locations
for montgomery, tx


Map of Montgomery TX
Kelly S.

Kelly S.


Job Checkin

We performed two system ac tune. We discovered on tune up the upstairs with zoning had leaking return, bad start capacitor on blower, low on refrigerant, leaking evaporator coil, water condensation on the evaporator coil casing and heavily restricted condenser coil. The temperature split for the upstairs zone system: supply 63.7 Return 74.3 DT 10.6 -Repairs needed on the upstairs system. Need to replace leaking evaporator coil, disassemble the condenser casing to properly chemical clean condenser coil to remove heavily debris from coil to insure proper air flow, replace the blower motor capacitor so the blower motor doesn’t burn up. We need to reseal return so it’s not sucking attic air that is unfiltered and unconditioned. The downstairs system: We discovered the blower motor capacitor is vary week and needs to be replaced. The condenser coil is restricted and the condenser casing needs to be disassembled to chemical clean condenser coil for proper air flow. The system as also