32407 Tamina Rd Suite #7
Magnolia, TX 77354
832-458-0642

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 85 customer reviews

Great Company will continue to Use!!


Response from Dr. Rescue Comfort Specialist :

Thank you for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful experience with the ac tech


Response from Dr. Rescue Comfort Specialist :

Thank you for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Arrived on time and quickly solved our problem!


Response from Dr. Rescue Comfort Specialist :

Thank you for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

A/C Issue


Response from Dr. Rescue Comfort Specialist :

Thank you for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service


Response from Dr. Rescue Comfort Specialist :

Thank you for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Determination of issue

I am not pleased that logic board issue was diagnosed on the second attempt and after having an electrician come out to examine the electrical system. This determination should have been made on the first visit. It is now nearly a month later and now a proper diagnosis has been made. I hesitate to assign any stars because I have liked the service in the past and i do not want to affect the rating of the technician who came out today

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service.


Response from Dr. Rescue Comfort Specialist :

Thank you for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, just in time for summer!

Kelly and Max came out and were awesome. Professional yet still personable, knowledgeable and respectful of my home (even though it was a hot mess). I can already tell a big difference in the cooler temps throughout the house and they only left an hour ago! So pleased with their work that I signed up for the maintenance package for the year. Thank you for your prompt, quick and quality service. Highly recommended!


Response from Dr. Rescue Comfort Specialist :

Thank you so much for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Isaiah was an awesome tech


Response from Dr. Rescue Comfort Specialist :

Thank you for your review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service


Response from Dr. Rescue Comfort Specialist :

Thank you for your 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Kelly S.

Kelly S. Job Checkin

Installed warranty supplied evaporator coil and installed uncovered items and charge system and checked operations everything is working properly at this time.


Kelly S.

Kelly S. Job Checkin

Discovered plenum to be condensating. Need to reschedule for a camera inspection and possible sealant of the plenum.


Kelly S.

Kelly S. Job Checkin

Install new 5 Ton slab evaporator coil, new transition, drain pan, inline safety float switch, Mastic seal coil and modifications on supply plenum to fit new coil, recharge system to manufactures specs.


Kelly S.

Kelly S. Job Checkin

Discovered the condenser for the master bedroom and add on room to be leaking R22 Freon on the bottom of the coil. Minimum solution is to use repair kit to fix leak. This option is not recommended based on the age and condition of the condensing unit. The most cost efficient solution for reliable cooling is to replace the condenser and upgrade the system to 410A Freon.


Kelly S.

Kelly S. Job Checkin

Discovered leaking Lennox evaporator coil on upstairs system. Called in autho to 2-10HW waiting on autho from warranty company and homeowner. Claim is pending at this time based on decision.


Kelly S.

Kelly S. Job Checkin

Quotes only.


Kelly S.

Kelly S. Job Checkin

Discovered a failed start capacitor cap, installed new start capacitor and checked operations everything is working properly at this time. The condenser fan motor is shaking and vibrating the condenser unit, this will cause other damages if not replace. System is 13 years old, typically lifespan of a air conditioning system is 10 to 15 years. I do recommend a complete system replacement, It’s the only cost effective solution that will ensure reliable Ac performance.


Kelly S.

Kelly S. Job Checkin

Performed maintenance on 2 systems. Discovered on maintenance of downstairs system, found system low on Freon with a fouled condenser coil, & dual start capacitor has failed. Upstairs system findings on inspection / maintenance. Discovered dual start capacitor has failed, low on R22 freon, also has a fouled condenser coil. With a fouled condenser coil it will cause high pressures inside the system and will leak due to the high pressures of the refrigerant. The condenser coil being fouled, reducing systems ability to effectively dissipate the absorb heat from inside the home. The failed start capacitor will cause extensive damages to the condenser fan motor & compressor windings by not having current voltage. The will cause irreversible damages to windings. The evaporator coils are R22 only, need to update coil to R410A coil in order to replace the condenser units.


Kelly S.

Kelly S. Job Checkin

Performed complete performance inspection of both AC systems. No pending failures or deficiencies were present at time of service. Units are cooling properly, as designed.


Kelly S.

Kelly S. Job Checkin

Discovered upstairs condenser was slightly low on Freon. Homeowner declined to have leak search performed. Recommend to added in leak sealer and top off Freon to manufactures specs, instead of replacement. Checked upstairs system operations everything is working properly at this time.


Kelly S.

Kelly S. Job Checkin

Discovered upstairs condenser was slightly low on Freon. Installed leak sealer and recharge system to manufactures specs. Checked operations everything is working properly at this time.


Kelly S.

Kelly S. Job Checkin

Discovered dampers shot on upstairs 2 bedrooms, opened dampers to all rooms and checked airflow. Found the system to be low on Freon approximately 3-6lbs low. Need to have the drain pan, evaporator slab coil & along with sealing the system. Sending quote to have repairs done.


Kelly S.

Kelly S. Job Checkin

We will disassemble and thoroughly clean condensing unit. We will put the unit back together and install a start assist kit and surge protector to the unit to prevent unnecessary wear and tear. An overflow protection switch will be installed directly into the drain line to prevent damage to the ceiling and the drain pan in the attic.


Kelly S.

Kelly S. Job Checkin

Install 2.5T & 3.5T Trane 14SEER Complete System Replacements. 10Yr Labor Warranty, 10 Year Parts Warranty. We are going to temporarily fix upstairs system. Homeowner is keeping the old equipment. Please mail copies of warranty to homeowner.


Kelly S.

Kelly S. Job Checkin

Discovered that the compressor has failed and shorted out causing breaker to trip. Called into warranty company for AUTH waiting on decision if the homeowner wants to go with a compressor or upgrade system to R410 with 10 Year manufactures warranty. Homeowner is going with compressor replacement at this time.