Dan  P.

Dan P.


Job Checkin

Service for no water. Arrived to the home and found that the system has zero pressure and the minute you turn the power on it trips the breaker. The way the system is wired is incorrect. There is good connection for the wire going out of the home to the well. Tested the well pump and the pump motor is dead. Customer thinks the well is about 400 feet deep and is on stick pipe. Also the tank and wiring is wrong so it is recommended that the system be replaced or upgraded to a constant pressure. The well cap is not a water tight cap and there is ice build up on the wiring, recommend installing a water tight well cap on the well head. There is no ground wire running down to the pump so we will install the new pump with 3 wire plus ground and drop the well on schedule 120 pvc stick pipe. 12-22-21 return trip to upgrade the current well system to a constant pressure control system. The existing well system is not working at all so we cut out all the old equipment. When we pulled the well w