850 U.S. 9
Fishkill, NY 12524
845-896-4328

Job Locations
for marlboro, ny


Map of Marlboro NY
Scott Y.

Scott Y.


Job Checkin

C/S oil. Filter strainer and nozzle. Brushed and vacuumed. Combustion test. Boiler needs to be replaced. Boiler leaking from coil, coil is badly corroded and cannot be replaced, boiler from 1995. Customer will need to replace boiler, has comfort advisor coming out later today. System is running normally besides water leak from coil.