This is to repipe the small section at the bottom of the stairs and add a new clean out. We will replace all the old cast iron with pvc in that small area at bottom of the stairs Folks arrived on 09/24/2021 to repipe a small section of pipe at the bottom of the stairs. Upon arrival I started by cutting out the old section of cast iron that was being replaced. I then began to install new pvc I started with connecting a new y on the ground for the laundry tray to tie into. I then put another y for the main line coming from upstairs. I then installed a clean out to have access to clean the main line. I then connected to the other main line with a t and connected to the cast iron as well as the copper. I then connected back to the laundry tray and ran water in the whole house for a few minutes to check for leaks. There are no leaks at this time. I also let the customer know that the cast iron and copper line are in ok shape at this time but maybe something to think about replacing in the