Corey B.

Corey B.


Job Checkin

Customer called us out because the compressor is not coming online. Upon investigation, Troy found that the contact which had some organic material wedged between it and the contact, not allowing it to pass the electricity through. After removing the debris, the contact which works better. Quoted the customer on a new contactor, just in case it happens again and also a pound of Freon as the settings seemed a bit low, but only slightly. Also system is undersized by about a half a ton and system will never keep up with what they’re actually demanding it for.

Customer called us out because the compressor is not coming online. Upon investigation, Troy found that the contact which had some organic material wedged between it and the contact, not allowing it to pass the electricity through. After removing the debris, the contact which works better. Quoted the customer on a new contactor, just in case it happens again and also a pound of Freon as the settings seemed a bit low, but only slightly. Also system is undersized by about a half a ton and system will never keep up with what they’re actually demanding it for.