10103 Iron Rock Way
Elk Grove, CA 95624
833-569-0301

Job Locations
for el dorado hills, ca


Map of El Dorado Hills CA
Drew R.

Drew R.


Job Checkin

Kitchen drain broken and leaking through subfloor into crawl space, drain material made of ABS, per home owner, house was made in ‘89, house was piped in “Gable” ABS, ABS proven to be defective at glue joints and known to deteriorate over time Spot repair( temporary repair) to be done as of now due to cst request No warranty on spot repair or drain pipe due to condition of existing pipe Spot repair to consist of husky bands to connect to existing drain line, to remove up to 5ft of affected ABS to properly repair, also during initial investigations found similar piping through out house, located secondary spot that is leaking at joint of Wye along branch line Recommending branch lines in entirety under house to be removed and replaced with none defective pipe Clear impacted kitchen drain. Line with hydro jetter No warranty on repairs due to existing pipe defective type