10103 Iron Rock Way
Elk Grove, CA 95624
833-569-0301

Job Locations
for rocklin, ca


Map of Rocklin CA
Chris I.

Chris I.


Job Checkin

Customer request sidekick inspection service performed sidekick inspection service on split system Lennox inspected flame sensor remove and clean flame sensor checked and adjusted gas pressure to 1.7 inches of water column on stage one and 3.5 inches of water column on stage to verify that heating system is operating properly with a 49° temp rise inspected coolant system operation checked refrigerant level foundRefrigerant level is proper verified system operating properly with a 20° drop As per customer request Made adjustments to manual dampers closed upstairs bathroom 50% closed master upstairs to force more air to furthest bedroom Will re-check with customer next maintenance Customer used one sidekick and one repeat filter today customer has four Tune ups and 4 filters remaining