Job Checkin

Performed sidekick maintenance on 1 year old Goodman gas/electric split system located in closet/ground. Temp split and gas pressure are within specs. Cleaned all furnace components. Checked all electrical components and tightened all electrical connections. Everything on heating side is within specs. Switched to AC Checked refrigerant levels and temp split. Both within specs. Checked all electrical components and tightened all electrical connections. Compressor start amps over maximum allowed at 86.9 out of max 72.2. Everything else is within specs. Recommend adding a hard start kit and joining club membership to help keep the system running as efficiently as possible for as long as possible. System is operational and heating at this time