Perform a complete A/C inspection and provide detailed report of our findings. UNIT # 1 Kids Bedrooms/Upstairs 2 Zone System 1) Discovered 6" fresh air inlet with no damper controls. 2) System not equipped with UV Light protection. 3) System is not equipped with surge protection. 4) System has (1) float switch in emergency drain pan. 5) System not equipped with drain clean out. 6) Client explained that Son's front bedroom is a warm area. Downstairs zone thermostat in back hallway. Thermostat possibly satisfying before front room is satisfied. Adding averaging tempature sensors could address this issue. 7) Replaced F100 media filter. 8) Outside condenser coil needs to be chemical cleaned. UNIT # 2 Main Downstairs 1) Discovered 6" fresh air inlet with no damper controls. 2) System not equipped with UV Light protection. 3) System is not equipped with surge protection. 4) System has (1) float switch in emergency drain pan. 5) System not equipped with drain c