Sam J.

Sam J.


Job Checkin

Sam J - derived for summer service on a blue club member. Customer explained that the pool down staircase to the attic is damaged in a way that it cannot be climbed on or moved. He suggested to not worry about the indoor unit unless there was an issue. Replaced all the filters while testing. The thermostat operation then began servicing the system. Shut the power off to the condensing unit and clean the coil and also check the capacitor. Capacitor was weak and had been replaced previously due to the fact that the fan and compressor capacitor’s had been separated overtime. Customer approved replacing the bad capacitor which I did. Powered up unit and check the start up amperage of the compressor and condenser fan motor as well as run load amperage. Attached gauges and temperature probes to calculate superheat and sub cooling values. System is charged an operating to the manufacturer specifications. Spoke with homeowner and advised him on the status of the system, including