13SEP2024 Jason Brown Arrived for blue/silver AC tune up. Spoke with Paul about the systems performance. The house will freeze me out, but the mini split in my bonus room isn’t cooling very well. Inspected Carrier system. Verified evap And blower wheel are clean, checked amps and electrical connections. Spin wheel by hand to check balance. Washed condenser coils. Tested run capacitor and contactor, looked over fan motor and compressor. Carrier system is working properly at this time. 43/45 & 4/5 on the capacitor. Inspected mini split. Washed filters, and condenser coils. Inspected blower wheel coils. Checked temperature delta, supply temp reading 61-68. Spoke with homeowner about my findings. We decided to schedule the leak search for the spring tune up. Home system is cooling properly at this time. Mini split is not.