Job Locations
for bayboro, nc

David  S.

David S. Job Checkin

-Performed CMA Full Service on 3 Split Heat Pumps. -System 3 - 2018 Trane 4 Ton Split Heat Pump: Right Side of Space from Front: Outdoor fan motor capacitor tested weak. Recommend replacement of capacitor. Provided estimate for replacement of 7.5 mfd capacitor. Customer approves replacement of capacitor.


David  S.

David S. Job Checkin

-Performed CMA Full Service on 1 Trane Split Heat Pump at left parcel. -System 5 - 2019 Trane 3 Ton Split Heat Pump - Left Parcel: Observed flash code 2 (coil temp sensor out of range), 7 (timed defrost mode), 8 (timed defrost mode) upon arrival. Found coil temperature sensor resistance is not within range for actual temperature. Recommend replacing coil temperature sensor. Provided estimate for replacement of sensor.


David  S.

David S. Job Checkin

-Performed CMA Full Service on 1 Trane Split Heat Pump at middle parcel. -Sustem operating without challenge at this time.


Aidan T.

Aidan T. Job Checkin

{System #3} - Tech found thermostat calling for cool upon arrival, but outdoor unit not running. Contactor received 24v call and pulled in contacts. 240v power is present on line side but not on load side. - Replaced contactor and confirmed refrigerant charge and operation. - Outdoor ambient temp sensor was out of range causing a single flash code on defrost control. Tech reset the sensor and cleared code. - Advised customer that both capacitors are slightly weaker than their correct ratings. System is operating normally at this time. Thermostat set to 72 at tech departure.


Noah C.

Noah C. Job Checkin

Tech returned to replace blower motor/module. Tech tested system operation after new motor/module installation. System is back up and cooling, pressures are within spec.


Noah C.

Noah C. Job Checkin

Upon arrival tech found condenser 3 in a hard lockout due to multiple low pressure lockouts. Tech reset system and found suction pressure immediately drops upon startup. Tech inspected air handler and found blower not running. Tested module and found it to be receiving 240v as well as a 24v call. Motor and module have failed. Need to order motor and module and schedule repair.


Joshua C.

Joshua C. Job Checkin

Performed a full service maintenance on a Trane heat pump, changed filters, washed coils and unit, tested heat strips, blower, capacitors, amps, cleared drain traps, checked T-stat.


Joshua C.

Joshua C. Job Checkin

Performed a full service maintenance on a Trane heat pump, changed filters, cleared trap, tested heat strips, capacitor, blower motor, checked T-stat. Washed coils and unit.


Joshua C.

Joshua C. Job Checkin

Performed a full service maintenance on 3 Trane heat pumps, changed filters, tested motors, heat strips, capacitors, cleared drain traps, washed coils and units. Checked T-stats.


Luis R.

Luis R. Job Checkin

Full service on 5 Trane heat pumps.