Tech found system shutting down every time ignition control board called for spark igniter to energize. See video. Tech inspected orange spark ignition wire and found no issues with wire. Tech tried heat cycle without wire plugged in and found same symptom. Tech diagnosed failed ignition control board. Tech tested cooling mode without issue. Customer declined maintenance. Approved ordering ignition control board.