2308 Indian Springs Rd
Dudley, NC 28333
(919) 734-9611

Our Top Cities


Job Locations
for fremont, nc


Map of Fremont NC
Aidan T.

Aidan T.


Job Checkin

— Customer reported that the LP tank was refilled around 2 weeks prior to this visit. — First ignition revealed low gas pressure in first stage at 2.20” WC. Tech adjusted to 6.54” WC, purged the gas line, decreased regulator pressure, and cleaned burners. Second stage LP pressure read 10.18 without adjustment. — Upon further inspection, tech observed the IGN board constantly sending 15V to the first stage terminals on the gas valve, with no call for heat. IGN board is faulty and needs to be replaced. — Draft inducer motor is over heating during operation but not over-amping. Tech recommends replacing the inducer motor to avoid future challenges. System is operating normally at this time with adjusted gas pressures. Service warranty.