2308 Indian Springs Rd
Dudley, NC 28333
(919) 734-9611

Local Reviews
for walstonburg, nc

Rated 4.8 out of 5 stars based on 9 customer reviews

Excellent Service!

Ricardo is professional, personable and very knowledgeable. During his visit, he maintained three distinctly different systems of varying makes, models and ages. He replaced a capacitor in one and recommended a Soft Start Kit to extend the lifetime of a compressor in the oldest system. He treated us with respect while explaining the condition of each unit. I highly recommend Ricardo and the entire Jackson and Sons team.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Excellent service.

Well knowledgeable and he pin pointed the problem within mins of being here.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Good service

Senior citizen; all techs very professional and kind.The support staff kind as well.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Nice fellow; respecful; seemed to know problem,but same problem exists.......

Called ahead,timely,nice fellow.... Financial issue cost was over amount expected.Mom is recent widow,my dad died she's handling legalities and stretched thin. I was"" middle man." She was away fir pt catering job weekend I was house/ diog sitting only.......thought repair was comete,but same issue exists.AC fan outtside only working intermittently!!! Ran only about one hour.93 degrees....inside,only down to 85 degrees......Fan runs intermittently, then OFF...

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great service

Jesse was great took a great deal of time explaining everything

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great service to wire before it burn out

My experience was very satisfied with work and the service that Juan Provide the only thing was that he did not have but one new filter and I have two unit so he had to put back in the used one that he took out he said he was going to get the company to send me some so I will be waiting thanks

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great

Good job.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great service was Perform

Was First for Anthony been here with me and he was very good at what he was doing and to tell me what thing was like afterward

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Professional service

Mr. Holmes was thorough and professional in his work on my Trane unit. He identified the problem and found the solution quickly. He was patient with my questions and answered each question to my satisfaction. I trust Jackson and Son.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Job Locations
for walstonburg, nc

Jacobo C.

Jacobo C. Job Checkin

Remove 6 Ton Carrier Package Unit And Install New 6 Ton Trane Package Unit With WiFi Programmable Thermostat


Ricardo  T.

Ricardo T. Job Checkin

Tech washed and serviced unit and found no challenges at this time. Tech installed hard start and PSA 1 system.


Ricardo  T.

Ricardo T. Job Checkin

Tech washed and serviced unit and found run capacitor testing weak on split unit. Tech serviced unit and found no other challenges. Tech replaced cap.


David  S.

David S. Job Checkin

——Performed CMA Inspection on 5 Gas Package systems and 5 Split Systems. -System 1: 2018 Carrier 4 Ton Gas Package: Sanctuary Left: System operating without challenges at this time. -System 2: 2018 Carrier 4 Ton Gas Package: Sanctuary Right: System operating without challenges at this time. -System 3: 2021 Trane 3.5 Ton Gas Pack: Office & Bathrooms: System operating without challenges at this time. -System 4: 2000 Carrier 4 Ton Gas Package: Fellowship Hall: Found heat exchanger in poor condition, with heavy signs of rust, and signs of holes. This could present a safety issue due to presence of carbon monoxide. Heat exchanger should be replaced. Inducer draft motor housing is rusted and has holes, pulling outside air in not allowing heat to travel through heat exchanger. Tech deems heat is not safe to operate. Disconnected W terminal from control board. Office should provide estimate for replacement of heat exchanger. Office should provide estimate for replacement of inducer draft m


Mike A.

Mike A. Job Checkin

No financing


Spencer C.

Spencer C. Job Checkin

Tech found blower motor locked up and capacitor failed. Tech tested replacement capacitor and found blower still locked up indicating a failed blower. Tech found blower wheel is extremely dirty as well as filter. Tech found a visible leak in the evaporator coil. Compressor also failed meg test. Unit is 30 years old and needs replacing. Tech quoted replacing blower, repairing coil and replacing compressor.


Joseph C.

Joseph C. Job Checkin

Tech found float switch tripping due to debris in primary drain causing water to back up to float switch. Tech brushed and cleared drain with nitrogen and added union for easy access, no charge per recent visit.


Derek J.

Derek J. Job Checkin

Upon arrival tech was thermostat was not working. Tech found VP8000 showing double dash on screen and error code indicating a faulty sensor. Tech pulled faceplate off wall and reinstalled which cleared error. Tech checked thermostat reading and is reading accurately. Gave system a cooling call and temperatures are within a good range. Tech made estimate to replace thermostat and customer wanted to wait for now. Informed customer that it could happen again and could not guarantee how long it would stay operational. Emailed estimate for new thermostat to customer. System is back operational for now.


Noah C.

Noah C. Job Checkin

Replaced compressor. Vacuumed drain line from outside. Tested system operation, system is back up and cooling.


Jesse J.

Jesse J. Job Checkin

Tech returned to complete approved repairs. Tech replaced Fan Capacitors on Systems #7 and #8. Tech has attached pictures to invoice.


Noah C.

Noah C. Job Checkin

Tech waited for customer arrival to begin diagnosis of cooling issues. Provided recommendations for needed repairs.


Kyle W.

Kyle W. Job Checkin

THERMOSTAT WAS IN RECOVERY MODE DUE TO SYSTEM BEING DOWN PREVIOUSLY BYPASSING SCHEDULE. VERIFIED SCHEDULE IS SET TO 74 MON-FRI FROM 5-10PM, AND 80 FOR REMAINDER OF THE DAY. SET SAT-SUN TO 74 FROM 8AM-1PM, AND 80 FOR REMAINDER OF THE DAY. ALL SET-POINTS SET PER CUSTOMER REQUEST.


Kyle W.

Kyle W. Job Checkin

(UNIT #5) FOUND BLOWER MOTOR UNABLE TO RUN DUE TO FAILED RUN CAPACITOR. REPLACED CAPACITOR/INSTALLED SURGE PROTECTOR. SYSTEM BACK UP AND COOLING.


Chris M.

Chris M. Job Checkin

Replaced a 50 gallon propane water heater and added an expansion tank.


Noah C.

Noah C. Job Checkin

Tech returned to replace condenser fan motor with correct size. 1/4HP 825RPM. Tested system operation after installation of new motor, delta t and all amp draws are now within spec. System is cooling properly. Half of balance is already paid per office, rest of balance to be paid.