Excellent experience

Prompt, thorough,clean. Takes time to answer our questions, let us know how to prioritize future issues for planning purposes. Always polite, never tromp debris through the house. We have been happy customers for many years and plan to remain so.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Excellent same day service!

There is never a good time for the heat pump to break but Jackson and Sons always is right on it, usually seeing us the same day and gets us back up and running quickly and professionally. We are long term customers and plan to remain so.

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Great customer service

  • Overall Experience
  • Quality
  • Experience
  • Punctuality

Job Locations
for zebulon, nc

David  S.

David S. Job Checkin

-Performed CMA Filter Change at 4 back of house locations, 1 DOAS System, and rooftop gas packs per maintenance agreement.


Anthony  B.

Anthony B. Job Checkin

X


David  S.

David S. Job Checkin

-Performed CMA Full Service on 16 Split System Heat Pumps. Verified operation of oven hood exhaust fan and make up air. Multiple repairs or recommendations for replacement of systems were made at last service in October 2023. Updated estimates provided. -System 2: Old style thermostat in place in hallway but no longer in use. -System 5: Outdoor fan motor capacitor tested weak and was recommended for replacement at last service. Provided updated estimate $217.59. -System 6: Outdoor fan motor capacitor & compressor capacitor tested weak and were recommended for replacement at last service. Provided updated estimate $322.61. -System 8: Outdoor fan motor capacitor tested weak and was recommended for replacement at last service. Provided updated estimate $213.00 -System 9: Air handler blower motor capacitor tested weak and was recommended for replacement at last service. Provided updated estimate $217.59. -System 10: Air handler blower motor capacitor tested weak and was recommended f


Spencer C.

Spencer C. Job Checkin

Tech replaced and tested heat strip contactor and found heat strips working properly. Heat strips set off fire alarm and tech explained this was due to dust buildup on the heating elements from heat strips not running and assured no cause for concern.


Matt C.

Matt C. Job Checkin

Tech washed and serviced unit


Open T.

Open T. Job Checkin

Tech found no difficulties at this time. Homeowner extended Psa. Tech recommended plasma air.


Spencer C.

Spencer C. Job Checkin

Tech found thermostat constantly restarting and throwing insufficient voltage error. Heat strip contactor was shorted causing a voltage drop. Tech was told by Jeff to email estimate in order to get approval. Tech also found thermostat set to emergency heat. Tech removed the common wire from the limit switch connected to the contactor to allow system to run temporarily.


Ricardo  T.

Ricardo T. Job Checkin

Tech performed ESA wanded coils no leaks at this time. Tech found dark pitted contactor tech suggested replacing sent estimate. Dropped off 20x30x1 filter.


Landen  H.

Landen H. Job Checkin

Performed CMA inspection on 4 rooftop gas package systems, 2 make up air systems, and 1 DOAS system. Verified operation of exhaust fans. -RTU-2: During test cycle, compressor for circuit 1 does not operate. Unit transfers to compressor for circuit 2 at both stages of cooling test. Circuit 1 void of refrigerant. Recommend high level leak search. Provided estimate $385.63. -RTU-3: Gas heat cycled and immediately went off. Cleaned flame sensor and verified operation of heat. -Systems operating correctly at this time. Leak search needs to be performed on Gas Pack 2 circuit 1 (upon approval). Changed air filters at back of house location and left one case per agreement.


Landen  H.

Landen H. Job Checkin

-Performed CMA inspection on 7 split systems. -Split System 1: System recommended for replacement at previous service. System ~18 yr old. Uses R22 refrigerant. Compressor megged as bad with windings shorting. Observed pitting and signs of heat damage on compressor contactor. Recommend replacing. Provided estimate $252.55. Outdoor fan motor capacitor tested as weak. Provided estimate for capacitor at last visit. New estimate price $198.14. -Split System 2: Observed pitting on compressor contactor. Recommend replacing. Provided estimate $252.55. Replace battery warning on thermostat. Estimate provided at last visit. Provided updated estimate $29.40. Condenser ~18 yr old, AH~3 yr old. No heat strips installed in system. Uses R22 refrigerant. Due to age and type of condenser, customer should consider replacement of condenser. -Split System 3: System recommended for replacement at previous service. System ~18 yr old. Uses R22 refrigerant. Compressor megged as bad and compressor shorted


Jesse J.

Jesse J. Job Checkin

Tech preformed CMA FILTER CHANGE on 4 Gas Pack systems, 1 DOAS system, 1 MPU system, and 1 Air Makeup unit. Tech replaced all filters and washed and cleaned all washable filters.Tech has attached Filter Change reports to invoice along with pictures.


Open  T.

Open T. Job Checkin

-Performed CMA inspection on 16 split systems. Verified operation of oven hood exhaust fan and make up air. -System 2: Old style thermostat in place. Provided estimate for replacement if requested $652.31. -System 5: Outdoor fan motor capacitor tested weak. Provided estimate for replacement of capacitor $202.56. -System 6: Outdoor fan motor capacitor & compressor capacitor tested weak. Recommend replacement of dual run capacitor. Provided estimate $322.61. -System 8: Outdoor fan motor capacitor tested weak. Provided estimate for replacement of capacitor $198.14. Air handler blower motor capacitor tested weak. Provided estimate for replacement of capacitor $206.68. -System 9: Air handler blower motor capacitor tested weak. Provided estimate for replacement of capacitor $202.56. -System 10: Air handler blower motor capacitor tested weak. Provided estimate for replacement of capacitor $198.14. Compressor megged bad. Windings shorting and compressor is due for failure. System is R22,


Nate R.

Nate R. Job Checkin

Tech washed and serviced unit and found no challenges at this time. Customer extended esa via check 265.81 check number 5971 until is running and cooling with a delta t of 20 return temp 77 and a supply temp of 57. Have next tech in the area drop off 2 14x20x1 filters.


Nate R.

Nate R. Job Checkin

Tech washed and serviced unit at this time and found no challenges at this time. Tech recommended adding plasma air customer is very interested but would like to wait until next visit. Unit is running and cooling with a delta t of 20, return temp 72 and a supply of 52.


Noah C.

Noah C. Job Checkin

Upon arrival tech found supply run dripping water heavily off bottom side in kitchen area. Tech inspected rooftop package unit for kitchen area found no issues, return and supply line are dry. System is draining properly. Tech pulled whole drain pan and inspected for any cracks or leaks and found no challenges. Tech taped ripped area on insulation where water was leaking from. Tech stated to call if leak continues. May be possible roof leak.