Performed clean and check on AC system. Checked refrigerant charge and superheat, tested all electrical components, cleaned condenser coil, checked condensate drain, changed filter that customer provided, measured delta T, tested t-stat operations, cycled system in cooling. Found weak blower capacitor leaking oil.