8175 Camargo Road
Cincinnati, OH 45243
513-561-4888

Local Reviews

Rated 4.9 out of 5 stars based on 416 customer reviews

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Have been a client for 18 plus years. Technician always does a great job. Prices are excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Really great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Iona

Good service good communication

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work--again!

Professional and efficient!

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

always a good experience

Timely, efficient and always leave things extremely neat

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

No problem

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Nick was honest and forthright! He came into the home wearing “clean booties” over his boots. He supplied helpful and thoughtful info & knowledge!! Thank You, Nick!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellence as usual!

Professional and timely service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Nick H.

Nick H. Job Checkin

Started system in emergency heat tested and inspected all electrical components and controls insured proper stageing checked the filter and air flow to the system switched system to heat pump heating. Checked system charge and tested operation of the reversing valve confirmed proper operation of the defrost cycle.


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace. Conducted combustion analysis, measured temperature rise, tested all electrical components, inspected drains, gas supply, burner, inducer and blower assemblies, changed filter, and cycled system in heating. System is operating normally at this time.


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace and humidifier. Conducted combustion analysis, measured temperature rise, inspected gas supply, burner, inducer and blower assemblies, tested all electrical components, cleaned condensate trap and inspected drains, cleaned flame sensor, changed filter and humidifier pad. Cycled system in heating. System is operating normally at this time. Customer stated that the outdoor unit is unlevel. Found pad sunken on one side. Notified customer that we will relevel AC during spring maintenance check.


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace and humidifier. Cleaned flame sensor, tested all electrical components, inspected gas supply, drains, burner assembly, inducer and blower assemblies, conducted combustion analysis, measured temperature rise, and checked filter. HS ignitor is beginning to read high ohms but is still within range. Found bad humidistat and replaced it. System is operating normally at this time.


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace and humidifier. Customer had already changed humidifier pad. I replaced Aprilaire 213 filter. Conducted combustion analysis and measured temperature rise. Tested all electrical components and inspected burner, inducer and blower assemblies. Checked gas supply and drains. Customer stated that the thermostat kept changing temperature settings. I removed the existing schedule and set the stat to manual. System is operating normally at this time.


Drew R.

Drew R. Job Checkin

Found inducer assembly full of water due to a clog in condensate drain tube. Cleared clog and drained inducer. Performed clean and check on gas furnace. Tested all electrical components, inspected gas supply, drains, burner assembly, inducer and blower assemblies, conducted combustion analysis, measured temperature rise, checked filter and cycled system. Found high ohm reading on hs ignitor and clear signs of wear on filament. Notified customer that the ignitor is beginning to fail. Replaced HS ignitor. Cycled system in heating. Unit is operating normally at this time.


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace. Conducted combustion analysis, measured temperature rise, tested all electrical components, inspected gas supply, drains, inducer, burner and blower assemblies, cleaned flame sensor, cleaned condensate trap and changed filter. Found high CO readings on combustion analysis (1800ppm). Inspected flu pipe and fresh air pipe. Opened secondary fresh air port and CO readings dropped to 167ppm. Tested for CO in the house and ductwork, found no traces. Discussed issue with Nate. Notified customer of likely secondary heat exchanger beginning to fail. Discussed repair vs replace options but left furnace running as it is since CO levels are no longer in hazardous range. System is otherwise operating normally at this time.


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace and humidifier. Performed combustion analysis, tested all electrical components, inspected gas supply, drains, burner assembly, cleaned flame sensor, checked air filter and humidifier pad and measured temperature rise. Filter and humidifier pad are both in clean condition. Humidifier has a stuck solenoid. Needs replaced. System is otherwise operating normally at this time. Customer is interested in maintenance contract and wants humidifier repaired at a later date.


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace, humidifier, and ac. Conducted combustion analysis, measured temperature rise, tested all electrical components, condensate pump, inspected gas supply, flu, burner, inducer, and blower assemblies, cleaned flame sensor, changed filter and humidifier pad. Performed clean and check on AC unit. Checked refrigerant pressures, superheat and subcooling, tested all electrical components, measured temperature drop, and cleaned outdoor coil. Customer stated that the system would continuously run even when turned off at the thermostat. I found the fan option set to "on" causing the blower to run continuously. I switched it to "auto" and cycled the system in heating and then in cooling. System is operating normally at this time. Customer had $99.00 remaining on her account and I applied it to today's bill.


Drew R.

Drew R. Job Checkin

Performed clean and check on both gas furnaces. Conducted combustion analysis, tested all electrical components, inspected gas supply, drains, humidifier, burner assembly, flu, ductwork, cleaned flame sensors and measured temperature rise. Replaced Aprilaire 213 filter and humidifier pad P110-1245. Advised customer 16x25x1 filter needs replaced. Both systems are operating normally at this time.


Drew R.

Drew R. Job Checkin

Performed clean and check on oil furnace. Changed oil filter and nozzle. Changed air filter that customer provided. Conducted combustion analysis. Inspected and tested all electrical components. Blower capacitor is beginning to weaken but is still within range, notified customer. System is operating normally at this time. Customer signed up for maintenance contract and paid by check.


Drew R.

Drew R. Job Checkin

Performed clean and check on all 3 AHUs, both humidifiers, all 3 heat pumps; checked filters, changed humidifier pad P110-3545, inspected and tested all electrical components, drains, humidifier solenoids, water supply, humidifier drains, measured temperature rise, measured amp draws, tested capacitors, defrost cycle. Found bad capacitor on upstairs heat pump and replaced it. Customer renewed maintenance agreement. All systems are operating normally at this time.


Nathan  R.

Nathan R. Job Checkin

Collect club membership


Drew R.

Drew R. Job Checkin

Repaired damaged power wire to indoor unit and sealed hole with silcone. Recommended replacement of power/communication wire for mini split system. Found no damage to electrical wire other than the insulation coating, inspected system and found no further damage. System is operating normally at this time. Customer may be interested in maintenance contract going forward


Drew R.

Drew R. Job Checkin

Performed clean and check on gas furnace. Conducted combustion analysis, inspected drains and tested sump pump, gas supply, burner deck, tested all electrical components, checked filter and humidifier pad, and temperature rise. Humidifier pad is in like-new condition and filter is clean. System is operating normally at this time. Customer renewed maintenance contract